LOW COST WIRELESS ECG PATCH USING ESP32

  • Budi Sugandi Politeknik Negeri Batam
  • Muhammad Haikal Satria PT. Macan Teknologi Asia
  • Hamdani Arif Politeknik Negeri Batam
  • Nelmiawati Nelmiawati Politeknik Negeri Batam
  • Indra Hardian Mulyadi Politeknik Negeri Batam

Abstract

Wearable-and-wireless Electrocardiograph (ECG) has been widely used for long term monitoring due to practical reasons. Besides its high Signal to Noise Ratio (SNR), one of patch benefits is its flexibility for users to place the electrodes. However, most of existing commercial wireless ECG patches displays Heart Rate Variability (HRV) only, without ability to provide or record the ECG waveform. Some of them employ two electrodes only: Right Arm (RA) and Left Arm (LA), without additional electrode called Right Arm Drive (RLD). In addition, It is beneficial to provide more than one wireless technology option for ECG patch. We propose a low cost wireless ECG patch that has ability to provide ECG waveform (Lead I) and calculate HRV automatically. Besides RA and LA, it utilized RLD electrode to increase Common Mode Rejection Ratio (CMRR). For data processing, we employed ESP32, a low-power 32-bit microcontroller equipped with Bluetooth Classic (BT), Bluetooth Low Energy (BLE), and Wifi in a compact module. The test results showed that the proposed ECG patch resulted in more accurate HRV calculation as well as 2,7 times faster transition time compared to a commercial product.

References

[1] E. J. Benjamin, M. J. Blaha, S. E. Chiuve, M. Cushman, S. R. Das, R. Deo, S. D. d. Ferranti, J. Floyd, M. Fornage and C. Gillespie, "Heart Disease and Stroke Statistics-2017 Update: A Report From the American Heart Association," 2017.
[2] Pusdatin, "Info Data: Situasi Kesehatan Jantung," Jakarta, 2014.
[3] F. R. Hashim, Y. Januar, M. H. Mat, Z. I. Rizman and M. K. Awang, "Prediction of heart abnormality using MLP network," in AIP Conference Proceedings, 2018.
[4] M. R. Karaoğuz, E. Yurtseven, G. eAslan, B. G. Deliormanlı, ÖmerAdıgüzel, M. Gönen, K.-M. Li and E. N. Yılmazb, "The quality of ECG data acquisition, and diagnostic performance of a novel adhesive patch for ambulatory cardiac rhythm monitoring in arrhythmia detection," Journal of Electrocardiology, vol. 54, pp. 28-35, 2019.
[5] S. Hartikainen, J. A. Lipponen, P. Hiltunen, T. T. Rissanen, I. Kolk, M. P.Tarvainen, T. J.Martikainen, M. Castren, E.-S. Väliaho and H. Jäntti, "Effectiveness of the Chest Strap Electrocardiogram to Detect Atrial Fibrillation," The American Journal of Cardiology, vol. 123, no. 10, pp. 1643-1648, 2019.
[6] C. O. Avila, "Novel Use of Apple Watch 4 to Obtain 3-Lead Electrocardiogram and Detect Cardiac Ischemia," The Permanente Journal, vol. 23, pp. 99-102, 2019.
[7] T. Wu, J.-M. Redouté and M. Yuce, "A Wearable, Low-Power, Real-Time ECG Monitor for Smart T-shirt and IoT Healthcare Applications," in Advances in Body Area Networks, Springer, Cham, 2019, pp. 165-173.
[8] I. H. Mulyadi, J. Haueisen and E. Supriyanto, "Practical aspects in surface biopotential electrode placement for smart clothing: A simulation study," in Proceedings of the First International Symposium of Biomedical Engineering (ISBE 2016), Depok, 2017.
[9] J. Pan and W. J. Tompkins, "A Real-Time QRS Detection Algorithm," IEEE Transactions on Biomedical Engineering, Vols. BME-32, no. 3, pp. 230-236, March 1985.
[10] D. K. Hasibuan and I. H. Mulyadi, "Real-Time Heart Rate Monitoring for Wearable Electrocardiography Using Filter-Based and Peak Threshold Algorithms: A Comparative Study," Jurnal Integrasi, vol. 10, no. 2, pp. 54-58, October 2018.